Odrid HMI

Odrid HMI

Industrial grade HMI/SCADA

开发者: Jan Almqvist

中国
APP ID 复制
1066799333
分类
价格
129.00Kč
内购
0个评分
效率(付费)
昨日下载量
最近更新
2024-02-27
最早发布
2015-12-17
版本统计
  • 92天4小时

    最新版本上线距今

  • 3

    近1年版本更新次数

  • 2015-12-17

    全球最早版本上线日期

版本记录
显示信息
日期
  • 全部
每页显示条数
  • 请选择
  • 版本: 1.7.9

    版本更新日期

    2024-02-27

    Odrid HMI

    Odrid HMI

    Industrial grade HMI/SCADA

    更新日志

    1.7.9:

    Bug fixes/improvements in the protocol drivers for Modbus and Siemens S7 Communication (ISO-on-TCP).

    1.7.8:

    Error messages for different Siemens S7 String issues.
    Bug fix for system register 65452 (last Siemens S7 polled DBNO).
    Bug fix for lighted push button with a non zero register offset.
    The term 'Panel' is changed to 'Page'.

    视频/截图

    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图

    应用描述

    Operator panel for various industrial control system. Communication over Wi-Fi or mobile internet with the protocols Modbus/TCP (Class 0 and 1), Modbus RTU class 1 and Siemens S7 Communication (ISO-on-TCP).

    Odrid HMI is an alternative to traditional SCADA systems and operator panels. The app supports multiple data types and has easy navigation between pages using swipe gestures or buttons.

    Odrid HMI is also great to use for home automation with PLCs that have e.g. Modbus/TCP protocol is implemented to remotely control and monitor lighting, ventilation, heating etc in the residence or holiday home.

    Advantages:

    Excellent technical support.
    Free updates.
    Graphic HMIs with multi touch function can be created in minutes.
    Free-of-charge development tool with test run feature.
    Virtually unlimited number of pages, objects and variables.
    Does not require any third-party services.
    Genuine native app.

    Features:

    Parameters for communication such as IP address, port number, protocol, etc. can be specified per page.
    Automatic polling of all variables displayed in the current page, no need for separate tag list.
    Many formats for numeric variables such as 16 and 32 bit integer, unsigned, hex, ASCII, float (IEEE 754), etc.
    Prioritized event-driven transfer to the controller.
    Pages are edited in the measurement unit dp (Density Independent Pixels).
    Life bit for monitoring the operator panel in the controller. (Function similar to coordination area in Siemens S7.)
    Numeric variables can be displayed as predefined text for example alarms, sequence steps etc.
    Detailed diagnostics of connection and communication.
    Variable areas for system variables, local variables and constants.
    Possibility of automatic return to the start page after some time of inactivity.
    Selectable order for high and low words of 32-bit variables in the Modbus protocol.
    Poll interval can be set do save data traffic or battery.
    Support for Baltic, Central European, Chinese (GB2312, BIG5), Cyrillic, Eastern European, Greek, Hebrew, Japanese (Shift JIS), Turkish, Vietnamese and Western character sets.
    Ability to test run pages in the development tool.
    LED-objects can be displayed as rectangles and in any size e.g. for Andon-systems.
    Background color for pages can be selected.
    Modbus Device ID can be changed with GUI objects during operation.
    Image buttons.
    Password fields.
    Floating point and hexadecimal number formatting.
    Timestamp for page files.
    Hyperlinks.
    Document information in page files.

    Implemented protocols in the current version:

    Modbus/TCP: Class 0, Function 3 and 16. Reads and writes 64,512 holding registers.

    Modbus/TCP: Class 1, Function 1, 2, 4 and 5. Reads 65,535 discrete inputs, 65,535 input registers and reads and writes 65,535 outputs (coils).

    Modbus RTU: Class 0 and 1.

    Siemens S7 Communication: Reads and writes 8192 bytes in datablock 1 to 4095 and in the Input, Memory and Output areas.

    (Default value for highest Siemens S7 databock is 255.)

    Free-of-charge development tool for creating the pages to be used by Odrid HMI:
    https://www.idea-teknik.com/odrid_hmi_download.html

    Manual:
    https://www.idea-teknik.com/odrid_hmi_manual.html

    Version history:
    https://www.idea-teknik.com/odrid_hmi_version_history.html

    Modbus and Modbus/TCP are registered trademarks of Schneider Automation Inc.

    S7 and STEP 7 are trademarks of Siemens AG.
  • 版本: 1.7.7

    版本更新日期

    2023-12-19

    Odrid HMI

    Odrid HMI

    Industrial grade HMI/SCADA

    更新日志

    Version 1.7.7

    Bug fixes for the Register offset feature In the Modbus protocol drivers.

    Version 1.7.6

    New feature in the settings "Disconnect on rx timeout" for Modbus RTU.

    New system registers for Modbus RTU for enable and online per Device ID.

    Bug fixes.

    视频/截图

    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图

    应用描述

    Operator panel for various industrial control system. Communication over Wi-Fi or mobile internet with the protocols Modbus/TCP (Class 0 and 1), Modbus RTU class 1 and Siemens S7 Communication (ISO-on-TCP).

    Odrid HMI is an alternative to traditional SCADA systems and operator panels. The app supports multiple data types and has easy navigation between panels (pages) using swipe gestures or buttons.

    Odrid HMI is also great to use for home automation with PLCs that have e.g. Modbus/TCP protocol is implemented to remotely control and monitor lighting, ventilation, heating etc in the residence or holiday home.

    Advantages:

    Excellent technical support.
    Free updates.
    Graphic HMIs with multi touch function can be created in minutes.
    Free-of-charge development tool with test run feature.
    Virtually unlimited number of panels (pages), objects and variables.
    Does not require any third-party services.
    Genuine native app.

    Features:

    Parameters for communication such as IP address, port number, protocol, etc. can be specified per panel (page).
    Automatic polling of all variables displayed in the current panel (page), no need for separate tag list.
    Many formats for numeric variables such as 16 and 32 bit integer, unsigned, hex, ASCII, float (IEEE 754), etc.
    Prioritized event-driven transfer to the controller.
    Panels (pages) are edited in the measurement unit dp (Density Independent Pixels).
    Life bit for monitoring the operator panel in the controller. (Function similar to coordination area in Siemens S7.)
    Numeric variables can be displayed as predefined text for example alarms, sequence steps etc.
    Detailed diagnostics of connection and communication.
    Variable areas for system variables, local variables and constants.
    Possibility of automatic return to the start panel (page) after some time of inactivity.
    Selectable order for high and low words of 32-bit variables in the Modbus protocol.
    Poll interval can be set do save data traffic or battery.
    Support for Baltic, Central European, Chinese (GB2312, BIG5), Cyrillic, Eastern European, Greek, Hebrew, Japanese (Shift JIS), Turkish, Vietnamese and Western character sets.
    Ability to test run panels (pages) in the development tool.
    LED-objects can be displayed as rectangles and in any size e.g. for Andon-systems.
    Background color for panels (pages) can be selected.
    Modbus Device ID can be changed with GUI objects during operation.
    Image buttons.
    Password fields.
    Floating point and hexadecimal number formatting.
    Timestamp for panel (page) files.
    Hyperlinks.
    Document information in panel (page) files.

    Implemented protocols in the current version:

    Modbus/TCP: Class 0, Function 3 and 16. Reads and writes 64,512 holding registers.

    Modbus/TCP: Class 1, Function 1, 2, 4 and 5. Reads 65,535 discrete inputs, 65,535 input registers and reads and writes 65,535 outputs (coils).

    Modbus RTU: Class 0 and 1.

    Siemens S7 Communication: Reads and writes 8192 bytes in datablock 1 to 4095 and in the Input, Memory and Output areas.

    (Default value for highest Siemens S7 databock is 255.)

    Free-of-charge development tool for creating the panels (pages) to be used by Odrid HMI:
    https://www.idea-teknik.com/odrid_hmi_download.html

    Manual:
    https://www.idea-teknik.com/odrid_hmi_manual.html

    Version history:
    https://www.idea-teknik.com/odrid_hmi_version_history.html

    Modbus and Modbus/TCP are registered trademarks of Schneider Automation Inc.

    S7 and STEP 7 are trademarks of Siemens AG.
  • 版本: 1.7.5

    版本更新日期

    2023-08-01

    Odrid HMI

    Odrid HMI

    Industrial grade HMI/SCADA

    更新日志

    Bug fix for transparency in image buttons not working correctly.

    视频/截图

    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图

    应用描述

    Operator panel for various industrial control system. Communication over Wi-Fi or mobile internet with the protocols Modbus/TCP (Class 0 and 1), Modbus RTU class 1 and Siemens S7 Communication (ISO-on-TCP).

    Odrid HMI is an alternative to traditional SCADA systems and operator panels. The app supports multiple data types and has easy navigation between panels (pages) using swipe gestures or buttons.

    Odrid HMI is also great to use for home automation with PLCs that have e.g. Modbus/TCP protocol is implemented to remotely control and monitor lighting, ventilation, heating etc in the residence or holiday home.

    Advantages:

    Excellent technical support.
    Free updates.
    Graphic HMIs with multi touch function can be created in minutes.
    Free-of-charge development tool with test run feature.
    Virtually unlimited number of panels (pages), objects and variables.
    Does not require any third-party services.
    Genuine native app.

    Features:

    Parameters for communication such as IP address, port number, protocol, etc. can be specified per panel (page).
    Automatic polling of all variables displayed in the current panel (page), no need for separate tag list.
    Many formats for numeric variables such as 16 and 32 bit integer, unsigned, hex, ASCII, float (IEEE 754), etc.
    Prioritized event-driven transfer to the controller.
    Panels (pages) are edited in the measurement unit dp (Density Independent Pixels).
    Life bit for monitoring the operator panel in the controller. (Function similar to coordination area in Siemens S7.)
    Numeric variables can be displayed as predefined text for example alarms, sequence steps etc.
    Detailed diagnostics of connection and communication.
    Variable areas for system variables, local variables and constants.
    Possibility of automatic return to the start panel (page) after some time of inactivity.
    Selectable order for high and low words of 32-bit variables in the Modbus protocol.
    Poll interval can be set do save data traffic or battery.
    Support for Baltic, Central European, Chinese (GB2312, BIG5), Cyrillic, Eastern European, Greek, Hebrew, Japanese (Shift JIS), Turkish, Vietnamese and Western character sets.
    Ability to test run panels (pages) in the development tool.
    LED-objects can be displayed as rectangles and in any size e.g. for Andon-systems.
    Background color for panels (pages) can be selected.
    Modbus Device ID can be changed with GUI objects during operation.
    Image buttons.
    Password fields.
    Floating point and hexadecimal number formatting.
    Timestamp for panel (page) files.
    Hyperlinks.
    Document information in panel (page) files.

    Implemented protocols in the current version:

    Modbus/TCP: Class 0, Function 3 and 16. Reads and writes 64,512 holding registers.

    Modbus/TCP: Class 1, Function 1, 2, 4 and 5. Reads 65,535 discrete inputs, 65,535 input registers and reads and writes 65,535 outputs (coils).

    Modbus RTU: Class 0 and 1.

    Siemens S7 Communication: Reads and writes 8192 bytes in datablock 1 to 4095 and in the Input, Memory and Output areas.

    (Default value for highest Siemens S7 databock is 255.)

    Free-of-charge development tool for creating the panels (pages) to be used by Odrid HMI:
    https://www.idea-teknik.com/odrid_hmi_download.html

    Manual:
    https://www.idea-teknik.com/odrid_hmi_manual.html

    Version history:
    https://www.idea-teknik.com/odrid_hmi_version_history.html

    Modbus and Modbus/TCP are registered trademarks of Schneider Automation Inc.

    S7 and STEP 7 are trademarks of Siemens AG.
  • 版本: 1.7.4

    版本更新日期

    2023-05-23

    Odrid HMI

    Odrid HMI

    Industrial grade HMI/SCADA

    更新日志

    1.7.4

    Support for Vietnamese character set.

    1.7.3

    Bug fix for writing strings with reversed byte order using Modbus.
    The Slider object is disabled if the connected variable does not have a valid value.
    Improvement for System register R64542 (S7 DBNO) when using the Siemens S7 Communication (ISO-on-TCP) protocol.
    Minor changes in the Button and Input field objects.

    应用描述

    暂无应用描述数据

  • 版本: 1.7.2

    版本更新日期

    2022-12-27

    Odrid HMI

    Odrid HMI

    Industrial grade HMI/SCADA

    更新日志

    On the first page, the Home button in the Navigation bar is disabled instead of hidden to overcome the problem that the Home and Menu buttons were not aligned vertically on some devices.
    Bug fix for missing default value of 1 second for the sampling interval in the logging mode in the Line Graph object.
    Improvements for parsing the directives in the comment section for controlling the logging mode in the Line Graph object.

    视频/截图

    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图

    应用描述

    Operator panel for various industrial control system. Communication over Wi-Fi or mobile internet with the protocols Modbus/TCP (Class 0 and 1), Modbus RTU class 1 and Siemens S7 Communication (ISO-on-TCP).

    Odrid HMI is an alternative to traditional SCADA systems and operator panels. The app supports multiple data types and has easy navigation between panels (pages) using swipe gestures or buttons.

    Odrid HMI is also great to use for home automation with PLCs that have e.g. Modbus/TCP protocol is implemented to remotely control and monitor lighting, ventilation, heating etc in the residence or holiday home.

    Advantages:

    Excellent technical support.
    Free updates.
    Graphic HMIs with multi touch function can be created in minutes.
    Free-of-charge development tool with test run feature.
    Virtually unlimited number of panels (pages), objects and variables.
    Does not require any third-party services.
    Genuine native app.

    Features:

    Parameters for communication such as IP address, port number, protocol, etc. can be specified per panel (page).
    Automatic polling of all variables displayed in the current panel (page), no need for separate tag list.
    Many formats for numeric variables such as 16 and 32 bit integer, unsigned, hex, ASCII, float (IEEE 754), etc.
    Prioritized event-driven transfer to the controller.
    Panels (pages) are edited in the measurement unit dp (Density Independent Pixels).
    Life bit for monitoring the operator panel in the controller. (Function similar to coordination area in Siemens S7.)
    Numeric variables can be displayed as predefined text for example alarms, sequence steps etc.
    Detailed diagnostics of connection and communication.
    Variable areas for system variables, local variables and constants.
    Possibility of automatic return to the start panel (page) after some time of inactivity.
    Selectable order for high and low words of 32-bit variables in the Modbus protocol.
    Poll interval can be set do save data traffic or battery.
    Support for Baltic, Central European, Chinese (GB2312, BIG5), Cyrillic, Eastern European, Greek, Hebrew, Japanese (Shift JIS), Turkish and Western character sets.
    Ability to test run panels (pages) in the development tool.
    LED-objects can be displayed as rectangles and in any size e.g. for Andon-systems.
    Background color for panels (pages) can be selected.
    Modbus Device ID can be changed with GUI objects during operation.
    Image buttons.
    Password fields.
    Floating point and hexadecimal number formatting.
    Timestamp for panel (page) files.
    Hyperlinks.
    Document information in panel (page) files.

    Implemented protocols in the current version:

    Modbus/TCP: Class 0, Function 3 and 16. Reads and writes 64,512 holding registers.

    Modbus/TCP: Class 1, Function 1, 2, 4 and 5. Reads 65,535 discrete inputs, 65,535 input registers and reads and writes 65,535 outputs (coils).

    Modbus RTU: Class 0 and 1.

    Siemens S7 Communication: Reads and writes 8192 bytes in datablock 1 to 4095 and in the Input, Memory and Output areas.

    (Default value for highest Siemens S7 databock is 255.)

    Free-of-charge development tool for creating the panels (pages) to be used by Odrid HMI:
    https://www.idea-teknik.com/odrid_hmi_download.html

    Manual:
    https://www.idea-teknik.com/odrid_hmi_manual.html

    Version history:
    https://www.idea-teknik.com/odrid_hmi_version_history.html

    Modbus and Modbus/TCP are registered trademarks of Schneider Automation Inc.

    S7 and STEP 7 are trademarks of Siemens AG.
  • 版本: 1.7.1

    版本更新日期

    2022-11-29

    Odrid HMI

    Odrid HMI

    Industrial grade HMI/SCADA

    更新日志

    Bug fix for reading variables of type Coil and Discrete Input with address 0 in the protocol drivers for Modbus/TCP Class 1 and Modbus RTU Class 1.
    A message that tells the user why the app is requesting access to the local network.

    视频/截图

    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图

    应用描述

    Operator panel for various industrial control system. Communication over Wi-Fi or mobile internet with the protocols Modbus/TCP (Class 0 and 1), Modbus RTU class 1 and Siemens S7 Communication (ISO-on-TCP).

    Odrid HMI is an alternative to traditional SCADA systems and operator panels. The app supports multiple data types and has easy navigation between panels (pages) using swipe gestures or buttons.

    Odrid HMI is also great to use for home automation with PLCs that have e.g. Modbus/TCP protocol is implemented to remotely control and monitor lighting, ventilation, heating etc in the residence or holiday home.

    Advantages:

    Excellent technical support.
    Free updates.
    Graphic HMIs with multi touch function can be created in minutes.
    Free-of-charge development tool with test run feature.
    Virtually unlimited number of panels (pages), objects and variables.
    Does not require any third-party services.
    Genuine native app.

    Features:

    Parameters for communication such as IP address, port number, protocol, etc. can be specified per panel (page).
    Automatic polling of all variables displayed in the current panel (page), no need for separate tag list.
    Many formats for numeric variables such as 16 and 32 bit integer, unsigned, hex, ASCII, float (IEEE 754), etc.
    Prioritized event-driven transfer to the controller.
    Panels (pages) are edited in the measurement unit dp (Density Independent Pixels).
    Life bit for monitoring the operator panel in the controller. (Function similar to coordination area in Siemens S7.)
    Numeric variables can be displayed as predefined text for example alarms, sequence steps etc.
    Detailed diagnostics of connection and communication.
    Variable areas for system variables, local variables and constants.
    Possibility of automatic return to the start panel (page) after some time of inactivity.
    Selectable order for high and low words of 32-bit variables in the Modbus protocol.
    Poll interval can be set do save data traffic or battery.
    Support for Baltic, Central European, Chinese (GB2312, BIG5), Cyrillic, Eastern European, Greek, Hebrew, Japanese (Shift JIS), Turkish and Western character sets.
    Ability to test run panels (pages) in the development tool.
    LED-objects can be displayed as rectangles and in any size e.g. for Andon-systems.
    Background color for panels (pages) can be selected.
    Modbus Device ID can be changed with GUI objects during operation.
    Image buttons.
    Password fields.
    Floating point and hexadecimal number formatting.
    Timestamp for panel (page) files.
    Hyperlinks.
    Document information in panel (page) files.

    Implemented protocols in the current version:

    Modbus/TCP: Class 0, Function 3 and 16. Reads and writes 64,512 holding registers.

    Modbus/TCP: Class 1, Function 1, 2, 4 and 5. Reads 65,535 discrete inputs, 65,535 input registers and reads and writes 65,535 outputs (coils).

    Modbus RTU: Class 0 and 1.

    Siemens S7 Communication: Reads and writes 8192 bytes in datablock 1 to 4095 and in the Input, Memory and Output areas.

    (Default value for highest Siemens S7 databock is 255.)

    Free-of-charge development tool for creating the panels (pages) to be used by Odrid HMI:
    https://www.idea-teknik.com/odrid_hmi_download.html

    Manual:
    https://www.idea-teknik.com/odrid_hmi_manual.html

    Version history:
    https://www.idea-teknik.com/odrid_hmi_version_history.html

    Modbus and Modbus/TCP are registered trademarks of Schneider Automation Inc.

    S7 and STEP 7 are trademarks of Siemens AG.
  • 版本: 1.7.0

    版本更新日期

    2022-11-01

    Odrid HMI

    Odrid HMI

    Industrial grade HMI/SCADA

    更新日志

    New option "Always read full bytes" for Modbus.
    Support for Korean character set.
    Bug fixes.

    视频/截图

    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图

    应用描述

    Operator panel for various industrial control system. Communication over Wi-Fi or mobile internet with the protocols Modbus/TCP (Class 0 and 1), Modbus RTU class 1 and Siemens S7 Communication (ISO-on-TCP).

    Odrid HMI is an alternative to traditional SCADA systems and operator panels. The app supports multiple data types and has easy navigation between panels (pages) using swipe gestures or buttons.

    Odrid HMI is also great to use for home automation with PLCs that have e.g. Modbus/TCP protocol is implemented to remotely control and monitor lighting, ventilation, heating etc in the residence or holiday home.

    Advantages:

    Excellent technical support.
    Free updates.
    Graphic HMIs with multi touch function can be created in minutes.
    Free-of-charge development tool with test run feature.
    Virtually unlimited number of panels (pages), objects and variables.
    Does not require any third-party services.
    Genuine native app.

    Features:

    Parameters for communication such as IP address, port number, protocol, etc. can be specified per panel (page).
    Automatic polling of all variables displayed in the current panel (page), no need for separate tag list.
    Many formats for numeric variables such as 16 and 32 bit integer, unsigned, hex, ASCII, float (IEEE 754), etc.
    Prioritized event-driven transfer to the controller.
    Panels (pages) are edited in the measurement unit dp (Density Independent Pixels).
    Life bit for monitoring the operator panel in the controller. (Function similar to coordination area in Siemens S7.)
    Numeric variables can be displayed as predefined text for example alarms, sequence steps etc.
    Detailed diagnostics of connection and communication.
    Variable areas for system variables, local variables and constants.
    Possibility of automatic return to the start panel (page) after some time of inactivity.
    Selectable order for high and low words of 32-bit variables in the Modbus protocol.
    Poll interval can be set do save data traffic or battery.
    Support for Baltic, Central European, Chinese (GB2312, BIG5), Cyrillic, Eastern European, Greek, Hebrew, Japanese (Shift JIS), Turkish and Western character sets.
    Ability to test run panels (pages) in the development tool.
    LED-objects can be displayed as rectangles and in any size e.g. for Andon-systems.
    Background color for panels (pages) can be selected.
    Modbus Device ID can be changed with GUI objects during operation.
    Image buttons.
    Password fields.
    Floating point and hexadecimal number formatting.
    Timestamp for panel (page) files.
    Hyperlinks.
    Document information in panel (page) files.

    Implemented protocols in the current version:

    Modbus/TCP: Class 0, Function 3 and 16. Reads and writes 64,512 holding registers.

    Modbus/TCP: Class 1, Function 1, 2, 4 and 5. Reads 65,535 discrete inputs, 65,535 input registers and reads and writes 65,535 outputs (coils).

    Modbus RTU: Class 0 and 1.

    Siemens S7 Communication: Reads and writes 8192 bytes in datablock 1 to 4095 and in the Input, Memory and Output areas.

    (Default value for highest Siemens S7 databock is 255.)

    Free-of-charge development tool for creating the panels (pages) to be used by Odrid HMI:
    https://www.idea-teknik.com/odrid_hmi_download.html

    Manual:
    https://www.idea-teknik.com/odrid_hmi_manual.html

    Version history:
    https://www.idea-teknik.com/odrid_hmi_version_history.html

    Modbus and Modbus/TCP are registered trademarks of Schneider Automation Inc.

    S7 and STEP 7 are trademarks of Siemens AG.
  • 版本: 1.6.10

    版本更新日期

    2022-08-09

    Odrid HMI

    Odrid HMI

    Industrial grade HMI/SCADA

    更新日志

    1.6.10:
    Bug fix for input in the As Text format.

    1.6.9:
    When importing content, a warning is displayed before any files are overwritten.
    The change value dialog displays the name of the text list when using the As Text format.
    The Numeric variable object supports input in the As Text format.
    Support for Baltic character set.
    Support for Arabic character set.
    Bug fix for crash if panel (page) contains an image object without a filename.
    Bug fix for incorrect positioning of image objects during certain circumstances.

    视频/截图

    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图

    应用描述

    Operator panel for various industrial control system. Communication over Wi-Fi or mobile internet with the protocols Modbus/TCP (Class 0 and 1), Modbus RTU class 1 and Siemens S7 Communication (ISO-on-TCP).

    Odrid HMI is an alternative to traditional SCADA systems and operator panels. The app supports multiple data types and has easy navigation between panels (pages) using swipe gestures or buttons.

    Odrid HMI is also great to use for home automation with PLCs that have e.g. Modbus/TCP protocol is implemented to remotely control and monitor lighting, ventilation, heating etc in the residence or holiday home.

    Advantages:

    Excellent technical support.
    Free updates.
    Graphic HMIs with multi touch function can be created in minutes.
    Free-of-charge development tool with test run feature.
    Virtually unlimited number of panels (pages), objects and variables.
    Does not require any third-party services.
    Genuine native app.

    Features:

    Parameters for communication such as IP address, port number, protocol, etc. can be specified per panel (page).
    Automatic polling of all variables displayed in the current panel (page), no need for separate tag list.
    Many formats for numeric variables such as 16 and 32 bit integer, unsigned, hex, ASCII, float (IEEE 754), etc.
    Prioritized event-driven transfer to the controller.
    Panels (pages) are edited in the measurement unit dp (Density Independent Pixels).
    Life bit for monitoring the operator panel in the controller. (Function similar to coordination area in Siemens S7.)
    Numeric variables can be displayed as predefined text for example alarms, sequence steps etc.
    Detailed diagnostics of connection and communication.
    Variable areas for system variables, local variables and constants.
    Possibility of automatic return to the start panel (page) after some time of inactivity.
    Selectable order for high and low words of 32-bit variables in the Modbus protocol.
    Poll interval can be set do save data traffic or battery.
    Support for Baltic, Central European, Chinese (GB2312, BIG5), Cyrillic, Eastern European, Greek, Hebrew, Japanese (Shift JIS), Turkish and Western character sets.
    Ability to test run panels (pages) in the development tool.
    LED-objects can be displayed as rectangles and in any size e.g. for Andon-systems.
    Background color for panels (pages) can be selected.
    Modbus Device ID can be changed with GUI objects during operation.
    Image buttons.
    Password fields.
    Floating point and hexadecimal number formatting.
    Timestamp for panel (page) files.
    Hyperlinks.
    Document information in panel (page) files.

    Implemented protocols in the current version:

    Modbus/TCP: Class 0, Function 3 and 16. Reads and writes 64,512 holding registers.

    Modbus/TCP: Class 1, Function 1, 2, 4 and 5. Reads 65,535 discrete inputs, 65,535 input registers and reads and writes 65,535 outputs (coils).

    Modbus RTU: Class 0 and 1.

    Siemens S7 Communication: Reads and writes 8192 bytes in datablock 1 to 4095 and in the Input, Memory and Output areas.

    (Default value for highest Siemens S7 databock is 255.)

    Free-of-charge development tool for creating the panels (pages) to be used by Odrid HMI:
    https://www.idea-teknik.com/odrid_hmi_download.html

    Manual:
    https://www.idea-teknik.com/odrid_hmi_manual.html

    Version history:
    https://www.idea-teknik.com/odrid_hmi_version_history.html

    Modbus and Modbus/TCP are registered trademarks of Schneider Automation Inc.

    S7 and STEP 7 are trademarks of Siemens AG.
  • 版本: 1.6.5

    版本更新日期

    2022-05-03

    Odrid HMI

    Odrid HMI

    Industrial grade HMI/SCADA

    更新日志

    Bug fix for manipulating boolean variables mapped on bits in Modbus Holding registers.

    视频/截图

    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图

    应用描述

    Operator panel for various industrial control system. Communication over Wi-Fi or mobile internet with the protocols Modbus/TCP (Class 0 and 1), Modbus RTU class 1 and Siemens S7 Communication (ISO-on-TCP).

    Odrid HMI is an alternative to traditional SCADA systems and operator panels. The app supports multiple data types and has easy navigation between panels (pages) using swipe gestures or buttons.

    Odrid HMI is also great to use for home automation with PLCs that have e.g. Modbus/TCP protocol is implemented to remotely control and monitor lighting, ventilation, heating etc in the residence or holiday home.

    Advantages:

    Excellent technical support.
    Free updates.
    Graphic HMIs with multi touch function can be created in minutes.
    Free-of-charge development tool with test run feature.
    Virtually unlimited number of panels (pages), objects and variables.
    Does not require any third-party services.
    Genuine native app.

    Features:

    Parameters for communication such as IP address, port number, protocol, etc. can be specified per panel (page).
    Automatic polling of all variables displayed in the current panel (page), no need for separate tag list.
    Many formats for numeric variables such as 16 and 32 bit integer, unsigned, hex, ASCII, float (IEEE 754), etc.
    Prioritized event-driven transfer to the controller.
    Panels (pages) are edited in the measurement unit dp (Density Independent Pixels).
    Life bit for monitoring the operator panel in the controller. (Function similar to coordination area in Siemens S7.)
    Numeric variables can be displayed as predefined text for example alarms, sequence steps etc.
    Detailed diagnostics of connection and communication.
    Variable areas for system variables, local variables and constants.
    Possibility of automatic return to the start panel (page) after some time of inactivity.
    Selectable order for high and low words of 32-bit variables in the Modbus protocol.
    Poll interval can be set do save data traffic or battery.
    Support for Baltic, Central European, Chinese (GB2312, BIG5), Cyrillic, Eastern European, Greek, Hebrew, Japanese (Shift JIS), Turkish and Western character sets.
    Ability to test run panels (pages) in the development tool.
    LED-objects can be displayed as rectangles and in any size e.g. for Andon-systems.
    Background color for panels (pages) can be selected.
    Modbus Device ID can be changed with GUI objects during operation.
    Image buttons.
    Password fields.
    Floating point and hexadecimal number formatting.
    Timestamp for panel (page) files.
    Hyperlinks.
    Document information in panel (page) files.

    Implemented protocols in the current version:

    Modbus/TCP: Class 0, Function 3 and 16. Reads and writes 64,512 holding registers.

    Modbus/TCP: Class 1, Function 1, 2, 4 and 5. Reads 65,535 discrete inputs, 65,535 input registers and reads and writes 65,535 outputs (coils).

    Modbus RTU: Class 0 and 1.

    Siemens S7 Communication: Reads and writes 8192 bytes in datablock 1 to 4095 and in the Input, Memory and Output areas.

    (Default value for highest Siemens S7 databock is 255.)

    Free-of-charge development tool for creating the panels (pages) to be used by Odrid HMI:
    https://www.idea-teknik.com/odrid_hmi_download.html

    Manual:
    https://www.idea-teknik.com/odrid_hmi_manual.html

    Version history:
    https://www.idea-teknik.com/odrid_hmi_version_history.html

    Modbus and Modbus/TCP are registered trademarks of Schneider Automation Inc.

    S7 and STEP 7 are trademarks of Siemens AG.
  • 版本: 1.6.4

    版本更新日期

    2022-04-26

    Odrid HMI

    Odrid HMI

    Industrial grade HMI/SCADA

    更新日志

    Bug fix for reading 32-bit integer and floating point variables in the Modbus protocol drivers. (1.6.4)
    Bug fix for writing 32-bit integers in the Siemens S7 Communication (ISO-on-TCP) protocol driver. (1.6.3)
    Support for Hebrew character set. (1.6.2)

    视频/截图

    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图
    Odrid HMI App 截图

    应用描述

    Operator panel for various industrial control system. Communication over Wi-Fi or mobile internet with the protocols Modbus/TCP (Class 0 and 1), Modbus RTU class 1 and Siemens S7 Communication (ISO-on-TCP).

    Odrid HMI is an alternative to traditional SCADA systems and operator panels. The app supports multiple data types and has easy navigation between panels (pages) using swipe gestures or buttons.

    Odrid HMI is also great to use for home automation with PLCs that have e.g. Modbus/TCP protocol is implemented to remotely control and monitor lighting, ventilation, heating etc in the residence or holiday home.

    Advantages:

    Excellent technical support.
    Free updates.
    Graphic HMIs with multi touch function can be created in minutes.
    Free-of-charge development tool with test run feature.
    Virtually unlimited number of panels (pages), objects and variables.
    Does not require any third-party services.
    Genuine native app.

    Features:

    Parameters for communication such as IP address, port number, protocol, etc. can be specified per panel (page).
    Automatic polling of all variables displayed in the current panel (page), no need for separate tag list.
    Many formats for numeric variables such as 16 and 32 bit integer, unsigned, hex, ASCII, float (IEEE 754), etc.
    Prioritized event-driven transfer to the controller.
    Panels (pages) are edited in the measurement unit dp (Density Independent Pixels).
    Life bit for monitoring the operator panel in the controller. (Function similar to coordination area in Siemens S7.)
    Numeric variables can be displayed as predefined text for example alarms, sequence steps etc.
    Detailed diagnostics of connection and communication.
    Variable areas for system variables, local variables and constants.
    Possibility of automatic return to the start panel (page) after some time of inactivity.
    Selectable order for high and low words of 32-bit variables in the Modbus protocol.
    Poll interval can be set do save data traffic or battery.
    Support for Baltic, Central European, Chinese (GB2312, BIG5), Cyrillic, Eastern European, Greek, Hebrew, Japanese (Shift JIS), Turkish and Western character sets.
    Ability to test run panels (pages) in the development tool.
    LED-objects can be displayed as rectangles and in any size e.g. for Andon-systems.
    Background color for panels (pages) can be selected.
    Modbus Device ID can be changed with GUI objects during operation.
    Image buttons.
    Password fields.
    Floating point and hexadecimal number formatting.
    Timestamp for panel (page) files.
    Hyperlinks.
    Document information in panel (page) files.

    Implemented protocols in the current version:

    Modbus/TCP: Class 0, Function 3 and 16. Reads and writes 64,512 holding registers.

    Modbus/TCP: Class 1, Function 1, 2, 4 and 5. Reads 65,535 discrete inputs, 65,535 input registers and reads and writes 65,535 outputs (coils).

    Modbus RTU: Class 0 and 1.

    Siemens S7 Communication: Reads and writes 8192 bytes in datablock 1 to 4095 and in the Input, Memory and Output areas.

    (Default value for highest Siemens S7 databock is 255.)

    Free-of-charge development tool for creating the panels (pages) to be used by Odrid HMI:
    https://www.idea-teknik.com/odrid_hmi_download.html

    Manual:
    https://www.idea-teknik.com/odrid_hmi_manual.html

    Version history:
    https://www.idea-teknik.com/odrid_hmi_version_history.html

    Modbus and Modbus/TCP are registered trademarks of Schneider Automation Inc.

    S7 and STEP 7 are trademarks of Siemens AG.